Hotel Hypochlorous Acid Hocl Generator

SHC-200S Hypochlorous Acid Generator 


SHC-200S Hypochlorous Acid Generator is using the self-developed membrane  electrochemical technology, the safe, effective, non-toxic, non-irritating and environmentally friendly hypochlorous acid disinfection water in the range of 3-500ppm can be quickly and efficiently prepared in 1-3 seconds after starting the machine.


Model No.:                   SHC-200S

Water Production:        200L/hour

Concentration PPM:     50-500ppm

PH Concentration:        2.0-6.5

ORP:                             >800mv               


  Contact Now
Product Details

Hypochlorous Acid Generator  SHC-300S                                                                              

hypochlorous acid water maker.jpg

Advantage:


* Safe: 

In completely compliance with the national standards from <Hygienic requirements for disinfectants with chlorine>, <Hygienic requirements for acidic electrolyed water generator>.


* Efficient: 

1) Sterilization rate 99.99%; 

2) Sterilization time: within 1minute.


* Environmently Friendly: 

1) The pH value is between 5-6.5, it is slightly acidic, colorless, non-irritating, non-toxic, safe, harmless and no harm to the skin; 

2) It ends with water.


*Convenient and Economic:

Open and use, cleaning and disinfection two-in-one 


*Multiple Functions:

Sterilization, preservation, deodorization, pesticide residue removal, biofilm removal 



Scope of Application:   Hotels


Electrolyzed Hypochlorous Acid Water is an on-site generated eco-friendly sanitizer that can replace all chemicals used for cleaning and sanitizing hotel rooms, common areas, floors, and bathrooms.


SHINE systems are compact and easy to install.  Systems are designed to generate Hypochlorous Acid Water on-site and on-demand from an additive made yourself with just HCL and water.


Hocl generator hotel disinfection.jpg


Direct Application and Fogging


Being that hypochlorous acid is stable in solution, it can be applied through many different methods. In addition to direct application through spray bottles and mops, it can be applied broadly using foggers. Fogging offers many advantages in that it can distribute HOCL into a large area very quickly to sanitize and deodorize. Because HOCL is so safe, no protective gear or equipment is required. Fogging can also reach areas that are often missed by direct application such as under tables, chairs, and crevices that cannot be reached.


Hotel disinfection HOCL generator.jpg



Sanitizing Contact Surfaces


Not only is HOCL safe and all-natural, but it is more effective than the chemicals currently being used. HOCL is a solution of mixed oxidants of which the primary oxidant is eletrolytically generated hypochlorous acid (HOCl), an antimicrobial that has been recognized by the CDC in their guidelines for disinfection and sterilization. Hypochlorous acid can be applied at concentrations as high as 200 ppm which effectively inactivates most bacteria and viruses in less than 1 minute.


Hypochlorous acid generator.jpg



Linen Sanitation


HOCL Sanitizer can replace harsh chemicals such as quaternary ammonium (quats) used commonly to sanitize linens. Quats can cause eye irritation and contact dermatitis. For about 5% of people, quats are an extreme sensitizer and can cause a variety of asthma-like symptoms. HOCL Sanitizer is non-irritant and does not cause any respiratory or asthma-like symptoms.


HOCL generator.jpg



Employee Safety


Preparation of toxic concentrated chemicals can be a safety hazard for employees as they are respiratory and skin irritants. HOCL Cleaner & Sanitizer is 100% safe for employees. It does not require any special handling. It is non-irritant and does not require gloves or masks. It can be applied directly with rags and mops or broadly by fogging and pressure spraying.


HOCL generator.jpg




Product application video



Products Parameter:


Concentration PPM50ppm-500ppm
HOCl output200L/hour
Available chlorine concentration50ppm-500mg/L
ORP>800mv
Power requirementsAC220V 50Hz
Power0.35-3.2kw
Current setting value0.1-2.2A
ElectrolyteNaCl
Water inlet pressure0.15Mpa---0.25Mpa
Machine warranty1 year
Size600*500*1500mm




 

Available chlorine concentration testing video


pH value testing video



Our Factory:


Factory of hypochlorous acid generator.jpg

Shipment of Hypochlorous Acid Generator.jpg


Customers Visiting:

Shipment of Hypochlorous Acid Generator.jpg



Qualification Patent:


Qualification patant of Hypochlorous Acid Generator.jpg



Leave your messages

Popular products

We are the source manufacturer of electrolytic water industry for 26 years, electrolytic water equipment has been updated to V4.0, and there are 16 agents around the world.
x